返回数据集目录
任务型 RL专业研究英语

Expert-Research Medicine

复杂临床决策与医学研究任务

多系统推理安全评分项细粒度 Rubric
完整数据规模
1,200 任务
当前样例题目
3 项任务
样例文件数量
330
样例文件总体量
173.1 MB
题目与目录接口

在线预览仅展示题目与文件目录;完整原始样例包可登记后下载。

MED0058

Cardiac Critical-Care Device Consultation Request

Task

Cardiac Critical-Care Device Consultation Request

West China Hospital, Sichuan University — Cardiac Intensive Care Unit
Sent: 10 September 2025, 17:42 China Standard Time
To: Senior cardiologist, cardiac critical-care device consultation
From: CICU attending physician
Patient: Chen Yiming, hospital no. WC-250910-1842, bed CICU-07

Mr Chen is a 32-year-old man receiving femoral Impella CP support for fulminant myocarditis. Since this afternoon he has had recurrent suction alarms with worsening systemic perfusion and oxygenation, dark urine, and progressive loss of perfusion in the access-side foot. Vascular surgery, cardiac surgery, anesthesia, and perfusion are assembled; the hybrid room is being held from 18:10.

Please enter a time-stamped device consultation response by 18:00 with one integrated recommendation and the orders needed for the bedside and procedure teams to act now. The teams need your disposition of the current pump and your decision on whether a different support strategy should be activated.

Admission and Procedure Record

Date/timeEntry
9 Sep, 06:10Four days of fever, myalgia, and diarrhea followed by rapidly progressive dyspnea and hypotension. Previously independent; no known cardiac, vascular, renal, hepatic, or bleeding disorder. No drug allergy. Height 176 cm; pre-illness weight 72.0 kg.
9 Sep, 07:05Intubated for pulmonary edema and shock. Initial lactate 6.1 mmol/L despite norepinephrine and epinephrine.
9 Sep, 07:28TTE: LVEF 10%–15% with diffuse hypokinesis; LV end-diastolic diameter 48 mm; RV mildly dilated with moderately reduced systolic function; no pericardial effusion; native tricuspid aortic valve without stenosis or regurgitation.
9 Sep, 08:12Coronary angiography: no obstructive coronary disease. Endomyocardial biopsy obtained.
9 Sep, 09:05Impella CP with SmartAssist inserted through the right common femoral artery using the 14 Fr peel-away sheath. Device UDI 00813502012279; pump serial CP25-09173; Automated Impella Controller asset AIC-CCU-02. Pre-access angiography measured the right common femoral artery at 5.6 mm and the left at 7.2 mm, without stenosis or dissection. Distal right-leg flow remained visible after sheath placement, and no antegrade perfusion catheter was placed.
9 Sep, 09:12Pulmonary-artery catheter placed through the left internal jugular vein.
9 Sep, 09:22Fluoroscopy and TTE: inlet 3.4 cm below the aortic annulus, outlet above the valve, catheter directed toward the apex without mitral or ventricular-wall contact. Catheter mark at the sterile sleeve: 88.0 cm. Securing device locked. At P8, displayed flow 3.2–3.4 L/min with no alarm.
10 Sep, 15:50Preliminary biopsy: multifocal lymphocytic inflammatory infiltrate with myocyte injury; no giant cells on the sections reviewed. Final stains and viral studies pending.

During a sedation pause at 12:10 on 10 September, the patient opened his eyes, followed four commands, and moved all limbs. His wife is the documented surrogate while he is intubated; she requests full active treatment and has consented to extracorporeal support and vascular surgery if recommended. Advanced heart-failure review found no current contraindication to recovery-directed temporary support or later durable-support/transplant assessment.

Observation and Organ-Support Record

Pulmonary-artery catheter pressures are end-expiratory and zeroed at the phlebostatic axis. The wedge tracing was reconfirmed at 17:15. Cardiac output values are the median of three thermodilution measurements; an independently calculated Fick output at 17:20 was 2.8 L/min.

Time, 10 Sep08:0013:4017:20
Rhythm / heart rateSinus, 112/minSinus, 122/minSinus, 134/min
Arterial pressure / MAP91/59 / 72 mmHg85/57 / 68 mmHg78/50 / 62 mmHg
Norepinephrine0.12 microgram/kg/min0.18 microgram/kg/min0.30 microgram/kg/min
Epinephrine0.04 microgram/kg/min0.05 microgram/kg/min0.08 microgram/kg/min
Vasopressin——0.03 units/min
Right atrial pressure13 mmHg17 mmHg21 mmHg
Pulmonary artery pressure32/22 mmHg32/23 mmHg31/24 mmHg
Pulmonary capillary wedge pressure17 mmHg15 mmHg14 mmHg
Cardiac output / index3.8 L/min / 2.0 L/min/m²3.2 L/min / 1.7 L/min/m²2.7 L/min / 1.4 L/min/m²
Mixed venous oxygen saturation61%52%42%
Arterial lactate2.6 mmol/L4.0 mmol/L7.3 mmol/L
Urine output in preceding hour55 mL35 mL18 mL
VentilatorVC-CMV, FiO2 0.50, PEEP 8 cm H2OFiO2 0.65, PEEP 10 cm H2OFiO2 0.80, PEEP 14 cm H2O
SpO295%92%89%
  • At 14:25, the patient was turned for linen change with transient flexion of the right hip. The nurse then found the lateral edge of the catheter-securing pad lifted; the Tuohy-Borst valve remained closed.
  • At 15:08, 250 mL of 5% albumin was infused over 20 minutes for the recurrent alarm. Right atrial pressure increased from 18 to 21 mmHg; wedge pressure increased from 13 to 14 mmHg; cardiac output, MAP, and alarm frequency did not improve.
  • Net fluid balance since 08:00 on 9 September is +2.1 L; current weight is 74.4 kg. There has been no overt gastrointestinal, airway, urinary, retroperitoneal, or access-site bleeding. Abdomen is soft; both groins are dry without expanding hematoma.
  • ABG at 17:18 on FiO2 0.80 and PEEP 14 cm H2O: pH 7.24, PaCO2 39 mmHg, PaO2 60 mmHg, bicarbonate 16.8 mmol/L, lactate 7.3 mmol/L.
  • Portable chest radiograph at 16:35: bilateral diffuse air-space opacity, increased from morning; no pneumothorax. Impella course is seen across the aortic valve, but the inlet and outlet cannot be localized on this single projection.

Automated Impella Controller Record

Time, 10 SepSetting and displayed flowController and catheter observations
08:00P8; 3.2–3.4 L/minNo alarm. Aortic placement signal and pulsatile motor-current waveform. Purge pressure 510 mmHg; purge flow 11.4 mL/h. Catheter mark 88.0 cm.
14:31P8; repeated dips to 1.6–2.0 L/minFirst cluster of Suction alarms immediately after the bed turn. Motor-current pulsatility becomes nearly flat during each alarm and returns between alarms.
14:38P6; 2.5–2.7 L/minAlarms stopped for 9 minutes. MAP remained 61–64 mmHg on the then-current vasoactive doses.
14:49P8; 1.7–3.2 L/minP8 restored by the bedside fellow because systemic perfusion was worsening; suction alarms recurred within 2 minutes.
17:25P8; 1.5–3.2 L/minSuction alarms every 1–3 minutes. Placement signal remains aortic. No “position,” pump-stop, high-motor-current, purge, cable, controller, or power alarm. Purge pressure 535 mmHg; purge flow 11.8 mL/h. Catheter mark 89.5 cm.

The pump has remained connected to the same controller since insertion; there has been no controller transfer or loss of pump recognition. Both controller batteries show full charge, the unit is on AC power, and a charged backup controller with compatible cable and purge cassette is at the bedside.

Echocardiography Report

Urgent bedside TTE, 10 September 2025, 16:55–17:08

  • Parasternal long-axis and apical five-chamber measurements place the Impella inlet 5.2 cm below the aortic annular plane. The inlet/pigtail intermittently approaches the posteromedial papillary-muscle complex, and the catheter curves toward the inferolateral LV wall. The outlet color-flow artifact begins at the level of the aortic leaflets rather than clearly above them.
  • LV end-diastolic diameter is 31 mm at P8. LVEF remains approximately 10%. The native aortic valve does not open at P8.
  • RV basal diameter is 49 mm; fractional area change 14%; TAPSE 8 mm; tissue Doppler S′ 5 cm/s. The interventricular septum is flattened toward the LV in diastole. Moderate tricuspid regurgitation is present.
  • No pericardial effusion. No new mitral regurgitation, ventricular septal defect, or aortic regurgitation.
  • During a 90-second acquisition at P6, the LV end-diastolic diameter increased to 35 mm and the suction alarm ceased; the anatomic relation of the pump to the annulus and papillary muscle did not change. P8 was resumed after imaging at the bedside fellow’s request.

Laboratory and Medication Record

Test9 Sep 07:30, before support10 Sep 04:0010 Sep 13:3010 Sep 17:10
Hemoglobin142 g/L124 g/L112 g/L101 g/L
Platelets218 ×10⁹/L176 ×10⁹/L158 ×10⁹/L151 ×10⁹/L
Plasma-free hemoglobin—18 mg/dL34 mg/dL92 mg/dL
LDH418 U/L682 U/L966 U/L1,612 U/L
Haptoglobin0.82 g/L0.46 g/L0.17 g/L<0.10 g/L
Indirect bilirubin10 micromol/L17 micromol/L25 micromol/L39 micromol/L
Creatinine82 micromol/L94 micromol/L119 micromol/L158 micromol/L
Potassium4.1 mmol/L4.3 mmol/L4.7 mmol/L5.1 mmol/L

The 17:10 plasma-free hemoglobin sample was drawn from the left radial arterial line after a 10 mL discard and carried no in-vitro hemolysis flag. A separately drawn sample at 17:22 measured 89 mg/dL. Urine at 17:05 was dark brown; dipstick showed 3+ blood with 0–2 red cells/high-power field. Direct antiglobulin test is negative. No red-cell transfusion has been given.

Active infusions and device-related orders at 17:30

  • Purge: dextrose 5% with unfractionated heparin 25 units/mL; controller-delivered rate 11.8 mL/h.
  • Systemic unfractionated heparin: 600 units/h. Active order target: anti-Xa 0.20–0.40 IU/mL. Anti-Xa values were 0.27 IU/mL at 13:30 and 0.29 IU/mL at 17:10.
  • Fibrinogen 2.2 g/L, INR 1.3, aPTT 52 seconds. No prior heparin exposure within 100 days; no clinical suspicion of HIT.
  • Norepinephrine, epinephrine, and vasopressin are running at the doses in the observation record. No pulmonary vasodilator is running.

Neurovascular Observation and Duplex Record

Time, 10 SepRight calf NIRSLeft calf NIRSRight lower limb
08:0067%69%Warm; capillary refill 2 seconds; dorsalis pedis and posterior tibial Doppler signals present.
14:0058%68%Cooler than left; capillary refill 3 seconds; Doppler signals weak.
15:3044%67%Pale forefoot; capillary refill 4 seconds; dorsalis pedis signal absent, posterior tibial signal intermittent.
17:2031%65%Cool pale foot; capillary refill 5 seconds; no dorsalis pedis or posterior tibial arterial signal. On sedation pause, the patient reports numbness confined to the toes and distal forefoot; ankle and toe movement remain full. Popliteal arterial signal is monophasic; venous Doppler signal is present.

Duplex ultrasound, 17:28: The Impella sheath occupies most of the right common femoral arterial lumen. Color flow passes around the sheath only intermittently. Distal superficial femoral and popliteal flow is low-velocity and monophasic. No discrete arterial thrombus, dissection flap, pseudoaneurysm, or groin hematoma is seen. The profunda femoris remains patent. The left common femoral artery is patent and measures 7.2 mm.

Vascular surgery bedside note, 17:34: Both the attending vascular surgeon and interventional fellow are present. A 5–7 Fr antegrade perfusion set, crossover equipment, thrombectomy equipment, and open femoral-repair tray are available. They can begin in the hybrid room at 18:10 and request the device team’s decision on whether the right femoral pump must be preserved, exchanged, or removed before they select the vascular approach.

Shock-Team Operations Message

Recorded 10 September 2025, 17:38

  • A device-trained interventional cardiologist and a cardiac sonographer are at the bedside. TEE, fluoroscopy, cardiac anesthesia, vascular surgery, cardiac surgery, and perfusion will be ready in the hybrid room at 18:10.
  • A primed VA-ECMO circuit is available. Percutaneous left-femoral arterial/right-internal-jugular venous cannulation can begin in the hybrid room; antegrade left-leg perfusion equipment is present. Axillary-graft or central arterial cannulation would require an estimated additional 60–90 minutes.
  • One like-for-like Impella CP replacement pump is stocked. No Impella 5.5 or percutaneous right-sided pump is stocked. An IABP console and balloon are available. Cardiac surgery can provide operative venting if required.
  • The patient-specific device authorization permits continuation of the current Impella CP and one like-for-like exchange for up to 96 hours from implantation. The active bedside device file is Impella CP with SmartAssist document 0048-9007 revision rQ with the hospital’s acknowledged controller and positioning safety supplements. Repositioning or exchange must be performed by the listed trained cardiology or cardiac-surgery operators.
  • Inhaled nitric oxide can be connected within 10 minutes. Continuous renal-replacement therapy can be started within 30 minutes. Four crossmatched units of red cells are in the blood bank.
  • Repeat ABG/lactate turnaround is 15 minutes; plasma-free hemoglobin and anti-Xa turnaround is approximately 45 minutes.

Harbor submission

Write the complete response to the professional assignment above in /app/output/answer.md as UTF-8 Markdown. Include the required reasoning, calculations, tables and conclusions in that file; it is the submission read by the verifier. You may use local calculation tools.

题目文件:MED0058/instruction.md